GL-P series boiler grate speed reducer
Product Brief
GL-P series boiler grate speed reducer, adopts 3K structure of involute gear planetary drive and equilibrating load mechanism, has the characteristics of power flow, stepless speed adjustment with the electromagnetic adjustable speed motor and controller, a wide range of speed regulation, convenient use, stable and reliable performance, and is provided with reliable overload protection.
The series reducer adopts the optimized design, advanced structure, compact structure, small volume, light weight, high efficiency, long service life, low noise, easy to repair.
The purpose of the product
GL-P series boiler grate speed reducer, mainly used for various types of coal burning boiler grate speed reducer, such as wood, is an ideal product for boiler grate driving device industry upgrading.
Working conditions
Total reduction ratio: 5278-8037
Output shaft speed range: 0.01555-0.2368r/min
Rated output torque: 5000-45000N.m
Boiler tonnage, 1-40 tons
The model significance
GL - 5PA
GL: boiler grate speed reducer
5PA: matching boiler No.
GL boiler grate speed reducer mounting dimensions
Boiler grate speed reducer model | H | A×B | A1×B1 | H1 | L | L1 | l | 4-b×lˊ | D | Matching boiler tonnage(t/h) |
GL-5PA | 190 | 150×420 | 270×460 | 610 | 610 | 260 | 85 | 4-20×50 | According to the userRequired | 2、4 |
GL-10P | 220 | 220×460 | 330×526 | 710 | 870 | 300 | 145 | 4-22×50 | 6 | |
GL-16P | 305 | 220×620 | 350×700 | 858 | 990 | 370 | 145 | 4-26×60 | 8、10 | |
GL-20P | 370 | 260×730 | 410×830 | 950 | 1080 | 410 | 145 | 4-26×80 | 15、20 | |
GL-30P | 370 | 260×730 | 410×830 | 950 | 1080 | 410 | 145 | 4-26×80 | 25 | |
GL-40P | 440 | 300×920 | 550×1000 | 1250 | 1130 | 490 | 200 | 4-32×100 | 35、40 | |
GL-100P | 470 | 400×1060 | 600×1200 | 1450 | 1360 | 630 | 220 | 4-32×100 | 65~100 |
Note: the above installation dimensions are for reference only, can be based on user needs and!
Boiler grate Reducer model | GL-5P | GL-5PA | GL-10P | GL-16P | GL-20P | GL-30P | GL-40P | |||||||
Total reduction ratio | 5278 | 7357 | 5564.7 | 5515 | 5682 | 5415.5 | 8037 | |||||||
Output shaft speed ranger/min | 0.02368-0.2368 | 0.01631-0.1631 | 0.02246-0.2246 | 0.02267-0.2267 | 0.02200-0.2200 | 0.02308-0.2308 | 0.01555-0.1555 | |||||||
Rated output torque N.m | 5000 | 5500 | 7000 | 10000 | 20000 | 30000 | 45000 | |||||||
Matching boiler tonnage t/h( Reference resources) | 1 , 2 ,( 4 ) | 4 (Special boiler) | 6 | 8 , 10 | 10 (Heavy fire grate) 15 , 20 | 20 (Heavy fire grate) 25 | 30 , 35 , 40 | |||||||
The electromagnetic adjustable speed motor | Model | YCT90-4B | YCT112-4A | YCT112-4B | YCT132-4A | YCT132-4B | YCT160-4A | YCT160-4B | ||||||
Power | 0.37 | 0.55 | 0.75 | 1.1 | 1.5 | 2.2 | 3 | |||||||
Speed | 125-1250( Stepless) (The best speed motor:500-1200 ) | |||||||||||||
The weight of reducer | 175 | 200 | 520 | 880 | 930 | 1050 | 1600 |